Gas-discharge switches RGU type

The main technical characteristics

.

 
  

Parameters of Gas-discharge switches RGU type

 
Table #1
¹ Spark gap        type Uop,        (kV) Imax,      (kA) The maximal charge, transferable for a pulse at Ò≤100µs,  
(K)
Tpul, (µs) Design life at Ò≤100 µs,       (K) Limiting frequency of operation, (Hz)
Overall dimensions, (mm)
Mass  (kg)
1 RGU-1-10-100 2-10 100 5 ≤100 2õ105 2÷30 Ø145õ60 3
2 RGU-1-20-100 4-20 100 5 ≤100 2õ105 2÷30 Ø145õ100 5
3 RGU-1-30-100 6-30 100 5 ≤100 2õ105 2÷30 Ø145õ100 5
4 RGU-1-40-100 8-40 100 5 ≤100 2õ105 2÷30 Ø145õ100 5
5 RGU-1-50-100 10-50 100 5 ≤100 2õ105 2÷30 Ø145õ100 5
6 RGU-1-75-100 15-75 100 5 ≤100 2õ105 2÷30 Ø145õ180 6
7 RGU-1-100-100 20-100 100 5 ≤100 õ105 2÷30 Ø145õ180 6
8 RGU-2-5-50 1-5 50 2,5 ≤100 õ105 2÷30 Ø90õ35 1
9 RGU-2-10-50 2-10 50 2,5 ≤100 õ105 2÷30 Ø90õ35 1
10 RGU-2-15-50 3-15 50 2,5 ≤100 õ105 2÷30 Ø90õ60 1,5
11 RGU-2-20-50 4-20 50 2,5 ≤100 õ105 2÷30 Ø90õ60 1,5
12 RGU-2-30-50 6-30 50 2,5 ≤100 õ105 2÷30 Ø90õ100 1,5
13 RGU-2-40-50 8-40 50 2,5 ≤100 õ105 ≤3 Ø90õ100 1,5
14 RGU-2-50-50 10-50 50 2,5 ≤100 õ105 ≤3 Ø90õ100 1,5
15 RGU-3-5-20 1-5 20 1 ≤100 5õ104 ≤3 Ø35õ35 0,3
16 RGU-3-10-20 2-10 20 1 ≤100 5õ104 ≤3 Ø35õ50 0,4
17 RGU-3-15-20 3-15 20 1 ≤100 5õ104 ≤3 Ø35õ50 0,4
18 RGU-3-20-20 4-20 20 1 ≤100 5õ104 ≤3 Ø35õ70 0,5
Notes:
  • * - with air blowing
  • ** - link to description

The range of working voltage in Table 1 is shown at constant atmosphere pressure. The current pointed is max. amplitude value of current. The Mass pointed without control device with the accuracy 20 %. The frequency is shown in Table 1 is max. frequency of switch operation with the blowing of working volume.

The main technical characteristics of control device and capacitor are shown in the Table 2.

Table #2
Supply
voltage,
V
Frequency
of supply
voltage,
Hz
Voltage
of control
signal,
V
Duration
of control
signal,
mks
Control
current,
A
Input
resistance,
Ohm
Output
voltage,
kV

22050+(5÷10)1÷500,1÷0,25025÷75
BackMain pageTop of page